With the PAC 2000 S you have the choice between cooling mode and ventilation of a room on hot days. With the help of the integrated room thermostat, the automatic mode independently selects one of the two functions according to the temperature of the air. For an optimal air distribution in the room, you can adjust the outflow direction variably and in 2 stages.
You may adjust the air conditioner PAC 2000 S in accordance with your requirements directly at its operating panel, or even more comfortable by infrared remote control from the couch.
The options of 24-hour timer, an air filter and the transport castor provide additional comfort. So you can transport the PAC 2000 S to other rooms rapidly. Furthermore it also acts as a dehumidifier and it helps to change the room climate into a pleasant atmosphere.
This air conditioner is GS safety certified and TÜV-tested and falls under the energy efficiency class A!
Technical data:
*at 30 °C and 70 % RH
Mobile Air Conditioners - Comfortable Chilling Machines
Note: No cooling without hose!
Do not let yourself be confused by pictures of the air-conditioners, which suggest a completely tubeless application - at least one hose is indispensable, even if you do not always see it!Why?
Professional home air-conditioning systems world-wide are all compression refrigeration systems. And these generate as much cold as heat - unalterable physics. The generated cold is desired in the room, but the heat is not. That's why it has to go outside.
In the case of split devices, it is automatically outside, because here, the heat is dissipated directly in the external condenser. Nevertheless, these devices also require a connection line for the circulating refrigerant, which ensures the refrigeration transport.
With monoblock construction, the heat is central in the unit and must therefore be directed to the outside without mixing it again with the interior air.
For this purpose, at least one exhaust air hose is used, which is therefore a fixed delivery component of every monoblock air-conditioning unit available on the market, even if it is not directly apparent in every application illustration.
You may adjust the air conditioner PAC 2000 S in accordance with your requirements directly at its operating panel, or even more comfortable by infrared remote control from the couch.
The options of 24-hour timer, an air filter and the transport castor provide additional comfort. So you can transport the PAC 2000 S to other rooms rapidly. Furthermore it also acts as a dehumidifier and it helps to change the room climate into a pleasant atmosphere.
This air conditioner is GS safety certified and TÜV-tested and falls under the energy efficiency class A!
Technical data:
- Type: monoblock system
- Suitable for rooms up to approx.: 26 m² / 65 m³
- Energy efficiency maximum load (the higher, the better): 2.6 EER
- Cooling capacity max.*: 2.0 kW (7,000 Btu)
- Dehumidification performance max.: 1.0 l / h
- Air flow rate max.: 320 m³/h
- Power input max.: 0,7 kW
- Input voltage: 230 V / 50 Hz
- Noise levell stage 1/2/3 (distance 1m): - / 52 / - dB(A)
- Noise emission according to EN ISO 3745:2012: 64 dB(A)
- Exhaust hose, length / ø mm: 1,500 mm / 120 mm
- Dimensions L x W x H: 305 x 420 x 636 mm
- Weight: 23 kg
*at 30 °C and 70 % RH
Mobile Air Conditioners - Comfortable Chilling Machines
Note: No cooling without hose!
Do not let yourself be confused by pictures of the air-conditioners, which suggest a completely tubeless application - at least one hose is indispensable, even if you do not always see it!Why?
Professional home air-conditioning systems world-wide are all compression refrigeration systems. And these generate as much cold as heat - unalterable physics. The generated cold is desired in the room, but the heat is not. That's why it has to go outside.
In the case of split devices, it is automatically outside, because here, the heat is dissipated directly in the external condenser. Nevertheless, these devices also require a connection line for the circulating refrigerant, which ensures the refrigeration transport.
With monoblock construction, the heat is central in the unit and must therefore be directed to the outside without mixing it again with the interior air.
For this purpose, at least one exhaust air hose is used, which is therefore a fixed delivery component of every monoblock air-conditioning unit available on the market, even if it is not directly apparent in every application illustration.
Technical data | ||
---|---|---|
General information | ||
Article number | 1.210.002.002 | |
Type | ||
Monobloc | ||
Split | ||
Cooling capacity | ||
Max. cooling capacity [kW] | 2 | |
Max. cooling capacity [Btu/h] | 7,000 | |
Recommended room size | ||
m³ | 65 | |
m² | 26 | |
Amount of air | ||
Stage Max. [m³/h] | 320 | |
Fan | ||
stages | 2 | |
Radial | ||
Dehumidification performance | ||
max. [l/h] | 1 | |
Attainable room temperature (min.) | ||
depending on operating conditions [°C] | 15 | |
Cooling medium | ||
Cooling medium | Air | |
Surrounding conditions | ||
Min. temperature range [°C] | 15 | |
Max. temperature range [°C] | 43 | |
Electrical values | ||
Mains connection | 230 V/50 Hz | |
Power input [kW] | 0.7 | |
Nominal current consumption [A] | 3.3 | |
Recommended fusing [A] | 10 | |
Electric connection | ||
Connection plug | CEE 7/7 | |
Cable length [m] | 1.8 | |
Compressor | ||
Type of cooling agent | R-410A | |
Amount of cooling agent [g] | 290 | |
GWP factor | 2,088 | |
CO2 equivalent [t] | 0.61 | |
Suction Side pressure [MPa] | 0.8 | |
Discharge Side Pressure [MPa] | 3.8 | |
Sound values | ||
Noise emission [dB(A)] according to EN ISO 3745:2012 | 64 dB(A) | |
Stage 1 - Distance 1 m [dB(A)] | 50 | |
Stage 2 - Distance 1 m [dB(A)] | 52 | |
Exhaust air hose | ||
Total length [m] | 1.5 | |
Diameter [mm] | 120 | |
Dimensions | ||
Length (packaging excluded) [mm] | 305 | |
Width (packaging excluded) [mm] | 420 | |
Height (packaging excluded) [mm] | 636 | |
Weight | ||
(packaging excluded) [kg] | 21 |
Equipment, features and functions | ||
---|---|---|
Condensate draining | ||
Exhaust air | ||
With water tank | ||
With condensate drain | ||
Available | ||
Water tank [l] | ||
Timer function | ||
Switch-on time preselectable | ||
Switch-off time preselectable | ||
Room thermostat | ||
Available | ||
Room air filter | ||
Readily accessible | ||
Cleanable | ||
Additional functions | ||
Adjustable air discharge direction | ||
Dehumidification function | ||
Ventilation function | ||
Automatic function | ||
Sleep mode | ||
Automatic error diagnosis | ||
Swing function | ||
Control panel | ||
Infrared remote control | ||
Electronic control panel | ||
Microprocessor-controlled operation | ||
LED display | ||
Membrane keys | ||
Mobility | ||
Carry/transport handle(s) | ||
Plastic wheels | ||
Rubber-tyred metal wheels | ||
Non-marking full-rubber wheels | ||
Swivel casters with parking brakes | ||
Adjustable bar handle | ||
Crane | ||
Forklift |